RW5-35 — 36 kV Porcelain Drop-Out Fuse Cutout
36kV (33–38kV) porcelain drop-out fuse cutout for high-voltage distribution and sub-transmission taps — high BIL and long creepage for the 35kV class.
✔ OEM / ODM · ✔ Porcelain & Polymer · ✔ Type-test reports · ✔ Reply in 24h
Overview
The RW5-35 is a 36 kV porcelain drop-out (expulsion) fuse cutout for overhead distribution networks. On fault, the fuse link melts, the arc is quenched inside the tube, and the tube drops by gravity to form a visible isolation gap — combining overcurrent protection and visible disconnection in one passive, hot-stick-operable device.
Available in 100 A and 200 A, common (drop-out) and load-break versions. Built and type-tested to IEC 60282-2 / GB 15166.3.
Technical Specifications — RW5-35
| Model | RW5-35 (porcelain) |
|---|---|
| Rated Voltage | 36 kV |
| Rated Current | 100 A / 200 A |
| Rated Breaking Current | On request |
| Lightning Impulse (BIL) | On request |
| Power-Frequency Withstand | On request |
| Creepage Distance | On request (per pollution grade) |
| Insulator | Porcelain |
| Standards | IEC 60282-2 / GB/T 15166.3 |
Full electrical ratings and type-test reports available on request — tell us your system voltage and fault level.
Range
| Model | Voltage | Current | Breaking | Weight |
|---|---|---|---|---|
| RW5-35/100 | 36 kV | 100 A | On request | On request |
| RW5-35/200 | 36 kV | 200 A | On request | On request |
Also available in other voltages (12 / 24 / 36 kV) and materials (porcelain & polymer) — see sidebar. 400 A and custom on request.
Key Features
Dual Function
Overcurrent protection + visible disconnection in one passive device.
Hot-Stick Operable
Open/close from the ground; ~25° downward tilt for positive drop-out.
Silver-Plated Contacts
Silver-plated copper contacts for low, stable contact resistance over decades of outdoor service.
IEC / GB Type-Tested
Breaking, impulse, dry/wet power-frequency and mechanical endurance per IEC 60282-2 / GB 15166.3.
Applications
Distribution Transformers
Primary-side protection for pole-mounted transformers.
Overhead Line Branches
Sectionalizing and overcurrent protection for laterals and taps.
Capacitor Banks
Overcurrent and switching-transient protection.
FAQ
Porcelain or polymer?
Common or load-break?
What breaking capacity do I need?
Need RW5-35 Cutouts for Your Project?
Specify voltage, current and quantity — we quote within 24 hours.