HRW11-10 — 12 kV Polymer (Silicone Rubber) Drop-Out Fuse Cutout
Silicone-rubber polymer-housed expulsion cutout for 12kV lines. Hydrophobic HTV insulator resists pollution flashover and salt-mist, won't shatter, and weighs about half of porcelain — ideal for coastal and high-pollution networks.
✔ OEM / ODM · ✔ Porcelain & Polymer · ✔ Type-test reports · ✔ Reply in 24h
Overview
The HRW11-10 is a 12 kV polymer drop-out (expulsion) fuse cutout for overhead distribution networks. On fault, the fuse link melts, the arc is quenched inside the tube, and the tube drops by gravity to form a visible isolation gap — combining overcurrent protection and visible disconnection in one passive, hot-stick-operable device.
Available in 100 A and 200 A, common (drop-out) and load-break versions. Built and type-tested to IEC 60282-2 / GB 15166.3.
Technical Specifications — HRW11-10
| Model | HRW11-10 (polymer) |
|---|---|
| Rated Voltage | 12 kV |
| Rated Current | 100 A / 200 A |
| Rated Breaking Current | On request |
| Lightning Impulse (BIL) | On request |
| Power-Frequency Withstand | On request |
| Creepage Distance | On request (per pollution grade) |
| Insulator | Polymer (Silicone Rubber) |
| Standards | IEC 60282-2 / GB/T 15166.3 |
Full electrical ratings and type-test reports available on request — tell us your system voltage and fault level.
Range
| Model | Voltage | Current | Breaking | Weight |
|---|---|---|---|---|
| HRW11-10/100 | 12 kV | 100 A | On request | On request |
| HRW11-10/200 | 12 kV | 200 A | On request | On request |
Also available in other voltages (12 / 24 / 36 kV) and materials (porcelain & polymer) — see sidebar. 400 A and custom on request.
Key Features
Dual Function
Overcurrent protection + visible disconnection in one passive device.
Hot-Stick Operable
Open/close from the ground; ~25° downward tilt for positive drop-out.
Anti-Pollution Silicone
Hydrophobic HTV silicone sheds water and resists tracking — for salt-mist and high-pollution coastal lines; won't shatter.
IEC / GB Type-Tested
Breaking, impulse, dry/wet power-frequency and mechanical endurance per IEC 60282-2 / GB 15166.3.
Applications
Distribution Transformers
Primary-side protection for pole-mounted transformers.
Overhead Line Branches
Sectionalizing and overcurrent protection for laterals and taps.
Capacitor Banks
Overcurrent and switching-transient protection.
FAQ
Porcelain or polymer?
Common or load-break?
What breaking capacity do I need?
Need HRW11-10 Cutouts for Your Project?
Specify voltage, current and quantity — we quote within 24 hours.
Request a Quote
Send your requirement, model or drawing — we reply within 24 hours.
Thank You!
Your inquiry has been received.
We’ll reply with a detailed quote within 24 hours.