Silicone rubber insulation cover for extra-large terminals & clamps — G10-07
The largest cover in the G10 terminal series, molded for the biggest cable lugs, busbar terminals and heavy bolted connections above 300 mm² — designed for main incomer cables, substation bus joints, and large transformer terminations.
✔ OEM / ODM · ✔ In-house tooling & molding · ✔ Type-test reports on request · ✔ Reply in 24h
The G10-07 is the extra-large cover in the G10 terminal insulation series — the biggest cover in the range, molded for the largest cable lugs, busbar terminals and bolted connections above 300 mm² conductor size. These are the heavyweight connections: main substation incomer cables, large power transformer terminations, MV busbar joints, and generator connections — connections that carry thousands of amps and where a single flashover can have catastrophic consequences.
At this scale, the terminal itself can be the size of a fist — and the bare metal surface area presents a substantial phase-to-ground and phase-to-phase risk. The G10-07’s robust, thick-wall HTV silicone body covers the entire connection assembly with generous creepage distance and a hydrophobic surface that actively prevents pollution tracking on the large metal surface — the single biggest failure mechanism for big outdoor terminals.
The largest sibling in the 4-size G10 family (02 → 05 → 06 → 07). Molded from HTV silicone — hydrophobic, UV-stable, anti-tracking, flame-retardant. Slip-on cap design with heavy-wall construction; live-line installable with appropriate hot-stick techniques for the terminal size. Full custom dimensional adjustments and OEM branding available — most G10-07 orders are custom-molded to the customer’s specific terminal dimensions.
| Model | G10-07 |
|---|---|
| Size | Extra-Large — for terminals and cable lugs > 300 mm² |
| Material | High-Temperature Vulcanized (HTV) Silicone Rubber (heavy-wall) |
| Designed For | Extra-large bolted terminals · main incomer lugs · power transformer terminations · MV bus joints · generator connections |
| Key Properties | Hydrophobic · UV-resistant · anti-tracking · flame-retardant · self-extinguishing |
| Operating Temperature | -60 °C ~ +200 °C |
| Color | Red (standard); Grey and custom available |
| Installation | Slip-on / cap-type (heavy-wall); live-line installable |
| Package | 3 PCS / SET |
| Standard | IEC / GB compliant; ISO 9001 factory |
| Customization | Custom-molded to your specific terminal/lug dimensions — standard on G10-07 orders |
Thickest silicone wall in the G10 range — built for the biggest, highest-current, most critical terminals in your network.
Most G10-07 orders are custom-molded to your exact terminal dimensions — send us a drawing or sample for a perfect fit.
Generous creepage distance on the oversized silicone body — the highest insulation margin in the G10 series.
Designed for connections where failure is not an option — main incomers, transformer primaries, generator terminals.
UV-stable, ozone-resistant, -60°C to +200°C — installed once, protects for decades.
G10-02 through G10-07 — one supplier covers every terminal size in your network, from control wire to main incomer.
Insulating the largest cable terminations where MV feeders enter primary substations — the highest-consequence connection point.
Covering MV and HV-side bushing terminals on power transformers up to several MVA.
Insulating bolted busbar connection joints in main switchgear bus runs.
Generator connections, large motor terminals, and heavy industrial feeder terminations.
Send terminal drawing, lug dimensions or sample — we’ll custom-mold and quote within 24h.